Table 2. Means and standard deviations (SD) of bone-to-implant contact (BIC) percentages in the cortical bone region of implants with different surface treatments at 15 and 45 days. |
Tabular Data - 504 B - 5 Variables, 5 Observations - UNF:6:/06x4gEQIYrhnffxEqMDlw==
Table 3. Means and standard deviations (SD) of bone-to-implant contact (BIC) percentages in the medullary bone region of implants with different surface treatments at 15 and 45 days.
|
Tabular Data - 505 B - 5 Variables, 5 Observations - UNF:6:OYS5F6NQIsj55jL7H7XKuQ==
Table 4. Means and standard deviations (SD) of Bone Area Fraction Occupancy (BAFO) percentages in the cortical bone region of implants with different surface treatments at 15 and 45 days. |
Tabular Data - 505 B - 5 Variables, 5 Observations - UNF:6:D9gsMyOwrWxbJy5VdOmrWA==
Table 5. Means and standard deviations (SD) of Bone Area Fraction Occupancy (BAFO) percentages in the medullary bone region of implants with different surface treatments at 15 and 45 days.
|
Tabular Data - 505 B - 5 Variables, 5 Observations - UNF:6:fzEo2l4El7sd+9vw04s8pg==
Table 6. Means and standard deviations (SD) of bone volume fraction (BV/TV) percentages in the medullary bone region of implants with different surface treatments at 15 and 45 days.
|
Tabular Data - 530 B - 5 Variables, 5 Observations - UNF:6:9BT2seQm8x4zvyrQdkRjlQ==
Table 7. Means and standard deviations (SD) of bone volume fraction (BV/TV) percentages in the cortical bone region of implants with different surface treatments at 15 and 45 days.
|
Tabular Data - 530 B - 5 Variables, 5 Observations - UNF:6:EwFWCfBBQr97bODlJVJYxg==
Table 8. Means and standard deviations (SD) of the trabecular bone thickness (Tb.Th), in millimeters, in the medullary bone region of implants with different surface treatments at 15 and 45 days.
|
Tabular Data - 514 B - 5 Variables, 5 Observations - UNF:6:JxaFA7frWUpkf3sxSBFdAw==
Table 9. Means and standard deviations (SD) of the trabecular bone thickness (Tb.Th), in millimeters, in the cortical bone region of implants with different surface treatments at 15 and 45 days.
|
JPEG Image - 93.5 KB -
MD5: 89777eb55cf9d192dcf69cd76567e586
Figure 1- Schematic drawing of the implant with the area represented by the “cortical bone” space measured by two valleys (in red) and the “cancellous bone” space measured by three valleys (in green). |
JPEG Image - 259.6 KB -
MD5: c435c441ecb8d863a6ffcf667b7bece5
Figure 2- SEM micro images at 10.000 × magnifications of the surface technological groups after treatment on the titanium implants of groups C (a); MN (b), MNSr (c), and MNSr+ (d). Below is Sr mapping by EDS (i; j). e–h show laser scanning confocal microscopy 3D reconstruction im... |